Sales & Support: Request A Quote
Home ProductsOzone Air Generator

ozone air generator, air ozonizer, continuous work, 50mg to 200 mg/h, remote control, disinfector for home and public

ozone air generator, air ozonizer, continuous work, 50mg to 200 mg/h, remote control, disinfector for home and public

    • ozone air generator,  air ozonizer, continuous work, 50mg to 200 mg/h, remote control, disinfector for home and public
    • ozone air generator,  air ozonizer, continuous work, 50mg to 200 mg/h, remote control, disinfector for home and public
    • ozone air generator,  air ozonizer, continuous work, 50mg to 200 mg/h, remote control, disinfector for home and public
  • ozone air generator,  air ozonizer, continuous work, 50mg to 200 mg/h, remote control, disinfector for home and public

    Product Details:

    Place of Origin: CHINA
    Certification: CE ROSH
    Model Number: GSL-2200A5

    Payment & Shipping Terms:

    Minimum Order Quantity: 1000 pcs
    Packaging Details: Box
    Delivery Time: 20 days
    Payment Terms: T/T
    Supply Ability: 5000 pcs per month
    Contact Now
    Detailed Product Description
    Voltage: DC 12V Power: 15W
    Cable: AC Adapter Ozone Output: 200mg/h, 100mg/h, 50mg/h
    Working Time: Constant Work, Continuous Repeat Control: Touch Screen, Remote Control
    Weight: 0.8kg

     
     
     

    Room air ozonizer, constant work and repeat work, 200mg/h, 100mg/h, 50mg/h

    air sterilizer for room air, hotel, elevator, greenhouse, public areas

    touch control and remote control

     
     
     

    VoltageDC 12Power15W
    CableAC adapterWorking modeconstantly working, repeat ON/OFF,
    Ozone output200mg, 100mg,50mgControltouch screen, remote control
    Size115*50*180mmWeight0.8kg


     
    Ozone, not only protects all lives on the earth from direct exposure to ultraviolet ray, but also is a strong oxidant, which can kill various kinds of germs and virus, decompose chemical material without any residue. It’s an excellent green environment-protection material, with unique advantages in health and epidemic prevention, living, treatment of industrial and agricultural water consumption and wate water.
     
     
    Function: Kill viruses and becateria in air and items surface, remove odor and bad smell.
     
    Application:
     
    1. Hospital-disinfection for wards, operation room and outpatient hall; kill virus and becateria in the air or on the surface of items;
     
    2. Hotel-disinfection of guestrooms, restaurants, kitchen, food pantries and rest rooms, remove bad smell and refresh air;
     
    3. Food factory-environmental disinfection in food processing plants;
     
    4. Slaughter house, Meat and poultry market-remove odor and bad smell, refresh air;
     
    5. Warehouse, storage room-environmental disinfection, remove odor and bad smell;
     
    6. Waiting hall of bus station and airport, coach, rest room-air disinfection, remove odor and refesh air;
     
    7. Disinfection of central air-conditioning duct;
     
    8. Newly furnitured house-remove formaldehyde, benzene,ammonia,carbon monoxide, kill germs and becateria in room air, remove smell and mould from furniture, purify air, specially applicable for cleaning kitchen and toilet.
     
     
    Safe concentration:
     
    The ozone concentration of people allowed to expose should be less than 0.2mg/m3. Industrial Hygienic standard of ozone: International Ozone Association: 0.1ppm, exposure for 10 hrs; Americal: 0.1ppm, exposure for 8 hrs; Germany, France, Japan: 0.1ppm; China: 0.15ppm. Ozone leak of Household Ozone disinfection cabinet should be less than 0.2mg/m3 (for distance of 1.5m more), residue concentration after one disinfection period should be less than 0.2mg/m3. Annimal tests shows, dividing point of ozone toxicity is 0.3ppm, while people can smell ozone in the air when concentration reaches 0.02-0.04ppm, according to the test of ozone toxicity to lung, the superior limit of ozone concentration is 1.5-2.0ppm. Ministry of Health stipulate the maximum allowable concentration is 0.2mg/m3.
     
    Concentration for air treatment. The required ozone concentration is low for air deodorization and sterilization, like 0.5ppm (1mg/m3), while for disinfection for items surface (kill microorganism and remove chemical pollution), the ozone concentration is required dozens of times higher. Ozone concentration for air treatment is among 1mg/m3~10mg/m3. It’s more efficient with low temperature and high humidity, especially the humidity, when it’s less than 45%, ozone is nearly useless for killing flowing microorganism in the iar, strengthens when it’s 60%, and most efficient when it’s 95%.
     
    Disinfection for food processing plant, 80% of natural germs can be killed with ozone concentration 0.5-1.0ppm.
     
    Ozone concentration for freezer disinfection is required 6-10ppm, keep freezer sealed after turing off machine for 24 hours, the removal rate of germs reaches 90% and mould for 80%.
     
    For fruit storge, can use ozone with concentration 2-3ppm to prevent restrain the growth of mould, the storage period can be extended twice.
     
    Application concentration for water treatment:
     
    The ozone centration for water treatment is between 0.1mg/L~10mg/L. The low value is minimum concentration for water disinfection and purification, the high value is the concentration which ozonated water disinfectors can reach.
     
    Ozone for tap water purification: International regular basis is solubility 0.4mg/L for 4 minutes, CT for 1.6.
     
    Ozone for residual chlorine: keep ozone concentration 0.1~0.5mg/L for 5-10minutes, can receive the effect of disinfection.
     
    Ozonated water for sterilization: Disinfection and terilization of ozonated water is rapid, when concentration reaches 0.3ppm, becateria can be killed with in 0.5-1.0 minute, HBV(hepatitis B virus) can be killed in 1 minute with concentration 4mg/l.
     
    Herbold reports: under 20℃, when ozone concentration reaches 0.43mg/L in water, 100% escherichia coli can be killed, while only 0.36mg/L is needed under 10 ℃. When ozone concentration reaches 0.25~38mg/L, HAV (hepatitis a virus) can be killed within several second or minutes.
     
    When ozone concentration reaches 0.4~0.5mg/L in mineral water, it can meet the requirements for sterilization and keep the quality, easonable ozone delivery is 1.5~2.0mg/L. Ozone concentration for bottled water should reach 0.3~0.5mg/L, the ozone delivery should meet the basis of 2g O₃ for 1 m³.
    ozone air generator,  air ozonizer, continuous work, 50mg to 200 mg/h, remote control, disinfector for home and publicozone air generator,  air ozonizer, continuous work, 50mg to 200 mg/h, remote control, disinfector for home and publicozone air generator,  air ozonizer, continuous work, 50mg to 200 mg/h, remote control, disinfector for home and public
    Main products: air purifier, home air cleaner, personal air purifier, personal ionizer, ozone generator, ozone machine, ozone air purifier, ozone water generator, ozone water purifier, continuous ozone machine, water ozonator, ozone air sterilizer, ozone water disinfector, vegetable ozone generator, portable ozone machine, wall mount ozone machine, 10 ozone generator, industrial ozone generator, commercial ozone equipment
     

    Contact Details
    Loyee Technology Co., Ltd

    Contact Person: Mr. Luo

    Tel: 86-0-15915419416

    Fax: 86-755-29968368

    Send your inquiry directly to us (0 / 3000)